<?xml version="1.0" encoding="utf-8"?>
<KNX xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" CreatedBy="KNX MT" ToolVersion="5.1.255.16695" xmlns="http://knx.org/xml/project/11">
<ManufacturerData>
<Manufacturer RefId="M-00FA">
<Catalog>
<CatalogSection Id="M-00FA_CS-1" Name="Geräte" Number="1" DefaultLanguage="de">
<CatalogItem Id="M-00FA_H-0-0_HP-0000-0A-0000_CI-0-1" Name="BME680 BSEC" Number="1" ProductRefId="M-00FA_H-0-0_P-0" Hardware2ProgramRefId="M-00FA_H-0-0_HP-0000-0A-0000" DefaultLanguage="de" />
</CatalogSection>
</Catalog>
<ApplicationPrograms>
<ApplicationProgram Id="M-00FA_A-0000-0A-0000" ApplicationNumber="0" ApplicationVersion="10" ProgramType="ApplicationProgram" MaskVersion="MV-57B0" Name="IP" LoadProcedureStyle="MergedProcedure" PeiType="0" DefaultLanguage="de" DynamicTableManagement="false" Linkable="false" MinEtsVersion="4.0">
<Static>
<Code>
<RelativeSegment Id="M-00FA_A-0000-0A-0000_RS-04-00000" Name="Parameters" Offset="0" Size="4" LoadStateMachine="4" />
</Code>
<ParameterTypes>
<ParameterType Id="M-00FA_A-0000-0A-0000_PT-Int" Name="Int">
<TypeNumber SizeInBit="32" Type="signedInt" minInclusive="0" maxInclusive="1000" />
</ParameterType>
</ParameterTypes>
<Parameters>
<Parameter Id="M-00FA_A-0000-0A-0000_P-1" Name="Zyklisch Senden" ParameterType="M-00FA_A-0000-0A-0000_PT-Int" Text="Sendeinterval (*3s)" Value="20">
<Memory CodeSegment="M-00FA_A-0000-0A-0000_RS-04-00000" Offset="0" BitOffset="0" />
</Parameter>
</Parameters>
<ParameterRefs>
<ParameterRef Id="M-00FA_A-0000-0A-0000_P-1_R-1" RefId="M-00FA_A-0000-0A-0000_P-1" />
</ParameterRefs>
<ComObjectTable>
<ComObject Id="M-00FA_A-0000-0A-0000_O-1" Name="Temperatur (raw)" Text="Temperatur (raw)" Number="1" FunctionText="Temperaturwert lesen (raw)" ObjectSize="2 Bytes" ReadFlag="Enabled" WriteFlag="Disabled" CommunicationFlag="Enabled" TransmitFlag="Enabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
<ComObject Id="M-00FA_A-0000-0A-0000_O-2" Name="Luftdruck" Text="Luftdruck" Number="2" FunctionText="Luftdruck lesen" ObjectSize="2 Bytes" ReadFlag="Enabled" WriteFlag="Disabled" CommunicationFlag="Enabled" TransmitFlag="Enabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
<ComObject Id="M-00FA_A-0000-0A-0000_O-3" Name="Widerstand (Gas)" Text="Widerstand (Gas)" Number="3" FunctionText="Widerstand lesen" ObjectSize="2 Bytes" ReadFlag="Enabled" WriteFlag="Disabled" CommunicationFlag="Enabled" TransmitFlag="Enabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
<ComObject Id="M-00FA_A-0000-0A-0000_O-4" Name="Luftfeuchtigkeit (raw)" Text="Luftfeuchtigkeit (raw)" Number="4" FunctionText="Luftfeuchtigkeit lesen (raw)" ObjectSize="2 Bytes" ReadFlag="Enabled" WriteFlag="Disabled" CommunicationFlag="Enabled" TransmitFlag="Enabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
<ComObject Id="M-00FA_A-0000-0A-0000_O-5" Name="Luftqualität" Text="Luftqualität" Number="5" FunctionText="Luftqualität lesen" ObjectSize="2 Bytes" ReadFlag="Enabled" WriteFlag="Disabled" CommunicationFlag="Enabled" TransmitFlag="Enabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
<ComObject Id="M-00FA_A-0000-0A-0000_O-6" Name="Genauigkeit der Luftqualität" Text="Genauigkeit der Luftqualität" Number="6" FunctionText="Genauigkeit lesen" ObjectSize="1 Byte" ReadFlag="Enabled" WriteFlag="Disabled" CommunicationFlag="Enabled" TransmitFlag="Enabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
<ComObject Id="M-00FA_A-0000-0A-0000_O-7" Name="Temperatur" Text="Temperatur" Number="7" FunctionText="Temperatur lesen" ObjectSize="2 Bytes" ReadFlag="Enabled" WriteFlag="Disabled" CommunicationFlag="Enabled" TransmitFlag="Enabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
<ComObject Id="M-00FA_A-0000-0A-0000_O-8" Name="Luftfeuchtigkeit" Text="Luftfeuchtigkeit" Number="8" FunctionText="Luftfeuchtigkeit lesen" ObjectSize="2 Bytes" ReadFlag="Enabled" WriteFlag="Disabled" CommunicationFlag="Enabled" TransmitFlag="Enabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
<ComObject Id="M-00FA_A-0000-0A-0000_O-9" Name="Trigger" Text="Trigger" Number="9" FunctionText="Messung auslösen" ObjectSize="1 Bit" ReadFlag="Disabled" WriteFlag="Enabled" CommunicationFlag="Enabled" TransmitFlag="Disabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
<ComObject Id="M-00FA_A-0000-0A-0000_O-10" Name="CO2" Text="CO2" Number="10" FunctionText="CO2 Äquivalent" ObjectSize="2 Bytes" ReadFlag="Enabled" WriteFlag="Disabled" CommunicationFlag="Enabled" TransmitFlag="Disabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
</ComObjectTable>
<ComObjectRefs>
<ComObjectRef Id="M-00FA_A-0000-0A-0000_O-1_R-1" RefId="M-00FA_A-0000-0A-0000_O-1" />
<ComObjectRef Id="M-00FA_A-0000-0A-0000_O-2_R-2" RefId="M-00FA_A-0000-0A-0000_O-2" />
<ComObjectRef Id="M-00FA_A-0000-0A-0000_O-3_R-3" RefId="M-00FA_A-0000-0A-0000_O-3" />
<ComObjectRef Id="M-00FA_A-0000-0A-0000_O-4_R-4" RefId="M-00FA_A-0000-0A-0000_O-4" />
<ComObjectRef Id="M-00FA_A-0000-0A-0000_O-5_R-5" RefId="M-00FA_A-0000-0A-0000_O-5" />
<ComObjectRef Id="M-00FA_A-0000-0A-0000_O-6_R-6" RefId="M-00FA_A-0000-0A-0000_O-6" />
<ComObjectRef Id="M-00FA_A-0000-0A-0000_O-7_R-7" RefId="M-00FA_A-0000-0A-0000_O-7" />
<ComObjectRef Id="M-00FA_A-0000-0A-0000_O-8_R-8" RefId="M-00FA_A-0000-0A-0000_O-8" />
<ComObjectRef Id="M-00FA_A-0000-0A-0000_O-9_R-9" RefId="M-00FA_A-0000-0A-0000_O-9" />
<ComObjectRef Id="M-00FA_A-0000-0A-0000_O-10_R-10" RefId="M-00FA_A-0000-0A-0000_O-10" />
</ComObjectRefs>
<AddressTable MaxEntries="255" />
<AssociationTable MaxEntries="255" />
<LoadProcedures>
<LoadProcedure MergeId="2">
<LdCtrlRelSegment AppliesTo="full" LsmIdx="4" Size="4" Mode="0" Fill="0" />
</LoadProcedure>
<LoadProcedure MergeId="4">
<LdCtrlWriteRelMem ObjIdx="4" Offset="0" Size="4" Verify="true" />
</LoadProcedure>
</LoadProcedures>
<Options />
</Static>
<Dynamic>
<ChannelIndependentBlock>
<ParameterBlock Id="M-00FA_A-0000-0A-0000_PB-1" Name="ParameterPage" Text="Allgemeine Parameter">
<ParameterRefRef RefId="M-00FA_A-0000-0A-0000_P-1_R-1" />
<ComObjectRefRef RefId="M-00FA_A-0000-0A-0000_O-1_R-1" />
<ComObjectRefRef RefId="M-00FA_A-0000-0A-0000_O-2_R-2" />
<ComObjectRefRef RefId="M-00FA_A-0000-0A-0000_O-3_R-3" />
<ComObjectRefRef RefId="M-00FA_A-0000-0A-0000_O-4_R-4" />
<ComObjectRefRef RefId="M-00FA_A-0000-0A-0000_O-5_R-5" />
<ComObjectRefRef RefId="M-00FA_A-0000-0A-0000_O-6_R-6" />
<ComObjectRefRef RefId="M-00FA_A-0000-0A-0000_O-7_R-7" />
<ComObjectRefRef RefId="M-00FA_A-0000-0A-0000_O-8_R-8" />
<ComObjectRefRef RefId="M-00FA_A-0000-0A-0000_O-9_R-9" />
<ComObjectRefRef RefId="M-00FA_A-0000-0A-0000_O-10_R-10" />
</ParameterBlock>
</ChannelIndependentBlock>
</Dynamic>
</ApplicationProgram>
</ApplicationPrograms>
<Hardware>
<Hardware Id="M-00FA_H-0-0" Name="BME680 BSEC IP" SerialNumber="0" VersionNumber="0" HasIndividualAddress="true" HasApplicationProgram="true" IsIPEnabled="true">
<Products>
<Product Id="M-00FA_H-0-0_P-0" Text="BME680 BSEC" OrderNumber="0" IsRailMounted="false" DefaultLanguage="de" />
</Products>
<Hardware2Programs>
<Hardware2Program Id="M-00FA_H-0-0_HP-0000-0A-0000" MediumTypes="MT-5">
<ApplicationProgramRef RefId="M-00FA_A-0000-0A-0000" />
</Hardware2Program>
</Hardware2Programs>
</Hardware>
</Hardware>
</Manufacturer>
</ManufacturerData>