<?xml version="1.0" encoding="utf-8"?> <KNX xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" CreatedBy="KNX MT" ToolVersion="5.6.407.26745" xmlns="http://knx.org/xml/project/11"> <ManufacturerData> <Manufacturer RefId="M-00FA"> <Catalog> <CatalogSection Id="M-00FA_CS-1" Name="Geräte" Number="1" DefaultLanguage="en-US"> <CatalogItem Id="M-00FA_H-00001-10_HP-0001-0B-0000_CI-123-1" Name="Schaltaktor" Number="1" ProductRefId="M-00FA_H-00001-10_P-123" Hardware2ProgramRefId="M-00FA_H-00001-10_HP-0001-0B-0000" DefaultLanguage="en-US" /> </CatalogSection> </Catalog> <ApplicationPrograms> <ApplicationProgram Id="M-00FA_A-0001-0B-0000" ApplicationNumber="1" ApplicationVersion="11" ProgramType="ApplicationProgram" MaskVersion="MV-57B0" Name="S20" LoadProcedureStyle="MergedProcedure" PeiType="0" DefaultLanguage="en-US" DynamicTableManagement="false" Linkable="false" MinEtsVersion="4.0"> <Static> <Code> <RelativeSegment Id="M-00FA_A-0001-0B-0000_RS-04-00000" Name="Parameters" Offset="0" Size="0" LoadStateMachine="4" /> </Code> <ParameterTypes /> <Parameters /> <ParameterRefs /> <ComObjectTable> <ComObject Id="M-00FA_A-0001-0B-0000_O-1" Name="Channel A" Text="Channel A" Number="1" FunctionText="Switch On/Off" ObjectSize="1 Bit" ReadFlag="Disabled" WriteFlag="Enabled" CommunicationFlag="Enabled" TransmitFlag="Disabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" /> <ComObject Id="M-00FA_A-0001-0B-0000_O-2" Name="Channel A" Text="Channel A" Number="2" FunctionText="Block" ObjectSize="1 Bit" ReadFlag="Disabled" WriteFlag="Enabled" CommunicationFlag="Enabled" TransmitFlag="Disabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" /> <ComObject Id="M-00FA_A-0001-0B-0000_O-3" Name="Channel A" Text="Channel A" Number="3" FunctionText="Status" ObjectSize="1 Bit" ReadFlag="Enabled" WriteFlag="Disabled" CommunicationFlag="Enabled" TransmitFlag="Enabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" /> </ComObjectTable> <ComObjectRefs> <ComObjectRef Id="M-00FA_A-0001-0B-0000_O-1_R-1" RefId="M-00FA_A-0001-0B-0000_O-1" /> <ComObjectRef Id="M-00FA_A-0001-0B-0000_O-2_R-2" RefId="M-00FA_A-0001-0B-0000_O-2" /> <ComObjectRef Id="M-00FA_A-0001-0B-0000_O-3_R-3" RefId="M-00FA_A-0001-0B-0000_O-3" /> </ComObjectRefs> <AddressTable MaxEntries="65000" /> <AssociationTable MaxEntries="65000" /> <LoadProcedures> <LoadProcedure MergeId="2"> <LdCtrlRelSegment AppliesTo="full" LsmIdx="4" Size="0" Mode="0" Fill="0" /> </LoadProcedure> <LoadProcedure MergeId="4"> <LdCtrlWriteRelMem ObjIdx="4" Offset="0" Size="0" Verify="true" /> </LoadProcedure> </LoadProcedures> <Options /> </Static> <Dynamic> <ChannelIndependentBlock> <ParameterBlock Id="M-00FA_A-0001-0B-0000_PB-1" Name="ParameterPage" Text="Allgemeine Parameter"> <ComObjectRefRef RefId="M-00FA_A-0001-0B-0000_O-1_R-1" /> <ComObjectRefRef RefId="M-00FA_A-0001-0B-0000_O-2_R-2" /> <ComObjectRefRef RefId="M-00FA_A-0001-0B-0000_O-3_R-3" /> </ParameterBlock> </ChannelIndependentBlock> </Dynamic> </ApplicationProgram> </ApplicationPrograms> <Hardware> <Hardware Id="M-00FA_H-00001-10" Name="Sonoff S20" SerialNumber="00001" VersionNumber="10" HasIndividualAddress="true" HasApplicationProgram="true" IsIPEnabled="true"> <Products> <Product Id="M-00FA_H-00001-10_P-123" Text="Schaltaktor" OrderNumber="123" IsRailMounted="false" DefaultLanguage="en-US" /> </Products> <Hardware2Programs> <Hardware2Program Id="M-00FA_H-00001-10_HP-0001-0B-0000" MediumTypes="MT-5"> <ApplicationProgramRef RefId="M-00FA_A-0001-0B-0000" /> </Hardware2Program> </Hardware2Programs> </Hardware> </Hardware> </Manufacturer> </ManufacturerData> </KNX>