<?xml version="1.0" encoding="utf-8"?>
<KNX xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" CreatedBy="KNX MT" ToolVersion="5.6.407.26745" xmlns="http://knx.org/xml/project/11">
  <ManufacturerData>
    <Manufacturer RefId="M-00FA">
      <Catalog>
        <CatalogSection Id="M-00FA_CS-1" Name="Geräte" Number="1" DefaultLanguage="en-US">
          <CatalogItem Id="M-00FA_H-00001-10_HP-0001-0B-0000_CI-123-1" Name="Schaltaktor" Number="1" ProductRefId="M-00FA_H-00001-10_P-123" Hardware2ProgramRefId="M-00FA_H-00001-10_HP-0001-0B-0000" DefaultLanguage="en-US" />
        </CatalogSection>
      </Catalog>
      <ApplicationPrograms>
        <ApplicationProgram Id="M-00FA_A-0001-0B-0000" ApplicationNumber="1" ApplicationVersion="11" ProgramType="ApplicationProgram" MaskVersion="MV-57B0" Name="S20" LoadProcedureStyle="MergedProcedure" PeiType="0" DefaultLanguage="en-US" DynamicTableManagement="false" Linkable="false" MinEtsVersion="4.0">
          <Static>
            <Code>
              <RelativeSegment Id="M-00FA_A-0001-0B-0000_RS-04-00000" Name="Parameters" Offset="0" Size="0" LoadStateMachine="4" />
            </Code>
            <ParameterTypes />
            <Parameters />
            <ParameterRefs />
            <ComObjectTable>
              <ComObject Id="M-00FA_A-0001-0B-0000_O-1" Name="Channel A" Text="Channel A" Number="1" FunctionText="Switch On/Off" ObjectSize="1 Bit" ReadFlag="Disabled" WriteFlag="Enabled" CommunicationFlag="Enabled" TransmitFlag="Disabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
              <ComObject Id="M-00FA_A-0001-0B-0000_O-2" Name="Channel A" Text="Channel A" Number="2" FunctionText="Block" ObjectSize="1 Bit" ReadFlag="Disabled" WriteFlag="Enabled" CommunicationFlag="Enabled" TransmitFlag="Disabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
              <ComObject Id="M-00FA_A-0001-0B-0000_O-3" Name="Channel A" Text="Channel A" Number="3" FunctionText="Status" ObjectSize="1 Bit" ReadFlag="Enabled" WriteFlag="Disabled" CommunicationFlag="Enabled" TransmitFlag="Enabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
            </ComObjectTable>
            <ComObjectRefs>
              <ComObjectRef Id="M-00FA_A-0001-0B-0000_O-1_R-1" RefId="M-00FA_A-0001-0B-0000_O-1" />
              <ComObjectRef Id="M-00FA_A-0001-0B-0000_O-2_R-2" RefId="M-00FA_A-0001-0B-0000_O-2" />
              <ComObjectRef Id="M-00FA_A-0001-0B-0000_O-3_R-3" RefId="M-00FA_A-0001-0B-0000_O-3" />
            </ComObjectRefs>
            <AddressTable MaxEntries="65000" />
            <AssociationTable MaxEntries="65000" />
            <LoadProcedures>
              <LoadProcedure MergeId="2">
                <LdCtrlRelSegment AppliesTo="full" LsmIdx="4" Size="0" Mode="0" Fill="0" />
              </LoadProcedure>
              <LoadProcedure MergeId="4">
                <LdCtrlWriteRelMem ObjIdx="4" Offset="0" Size="0" Verify="true" />
              </LoadProcedure>
            </LoadProcedures>
            <Options />
          </Static>
          <Dynamic>
            <ChannelIndependentBlock>
              <ParameterBlock Id="M-00FA_A-0001-0B-0000_PB-1" Name="ParameterPage" Text="Allgemeine Parameter">
                <ComObjectRefRef RefId="M-00FA_A-0001-0B-0000_O-1_R-1" />
                <ComObjectRefRef RefId="M-00FA_A-0001-0B-0000_O-2_R-2" />
                <ComObjectRefRef RefId="M-00FA_A-0001-0B-0000_O-3_R-3" />
              </ParameterBlock>
            </ChannelIndependentBlock>
          </Dynamic>
        </ApplicationProgram>
      </ApplicationPrograms>
      <Hardware>
        <Hardware Id="M-00FA_H-00001-10" Name="Sonoff S20" SerialNumber="00001" VersionNumber="10" HasIndividualAddress="true" HasApplicationProgram="true" IsIPEnabled="true">
          <Products>
            <Product Id="M-00FA_H-00001-10_P-123" Text="Schaltaktor" OrderNumber="123" IsRailMounted="false" DefaultLanguage="en-US" />
          </Products>
          <Hardware2Programs>
            <Hardware2Program Id="M-00FA_H-00001-10_HP-0001-0B-0000" MediumTypes="MT-5">
              <ApplicationProgramRef RefId="M-00FA_A-0001-0B-0000" />
            </Hardware2Program>
          </Hardware2Programs>
        </Hardware>
      </Hardware>
    </Manufacturer>
  </ManufacturerData>
</KNX>