knx/examples/knx-sonoffS20/knx-sonoffS20.xml
2019-01-03 22:20:50 +01:00

66 lines
4.3 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<KNX xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" CreatedBy="KNX MT" ToolVersion="5.6.407.26745" xmlns="http://knx.org/xml/project/11">
<ManufacturerData>
<Manufacturer RefId="M-00FA">
<Catalog>
<CatalogSection Id="M-00FA_CS-1" Name="Geräte" Number="1" DefaultLanguage="en-US">
<CatalogItem Id="M-00FA_H-00001-10_HP-0001-0B-0000_CI-123-1" Name="Schaltaktor" Number="1" ProductRefId="M-00FA_H-00001-10_P-123" Hardware2ProgramRefId="M-00FA_H-00001-10_HP-0001-0B-0000" DefaultLanguage="en-US" />
</CatalogSection>
</Catalog>
<ApplicationPrograms>
<ApplicationProgram Id="M-00FA_A-0001-0B-0000" ApplicationNumber="1" ApplicationVersion="11" ProgramType="ApplicationProgram" MaskVersion="MV-57B0" Name="S20" LoadProcedureStyle="MergedProcedure" PeiType="0" DefaultLanguage="en-US" DynamicTableManagement="false" Linkable="false" MinEtsVersion="4.0">
<Static>
<Code>
<RelativeSegment Id="M-00FA_A-0001-0B-0000_RS-04-00000" Name="Parameters" Offset="0" Size="0" LoadStateMachine="4" />
</Code>
<ParameterTypes />
<Parameters />
<ParameterRefs />
<ComObjectTable>
<ComObject Id="M-00FA_A-0001-0B-0000_O-1" Name="Channel A" Text="Channel A" Number="1" FunctionText="Switch On/Off" ObjectSize="1 Bit" ReadFlag="Disabled" WriteFlag="Enabled" CommunicationFlag="Enabled" TransmitFlag="Disabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
<ComObject Id="M-00FA_A-0001-0B-0000_O-2" Name="Channel A" Text="Channel A" Number="2" FunctionText="Block" ObjectSize="1 Bit" ReadFlag="Disabled" WriteFlag="Enabled" CommunicationFlag="Enabled" TransmitFlag="Disabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
<ComObject Id="M-00FA_A-0001-0B-0000_O-3" Name="Channel A" Text="Channel A" Number="3" FunctionText="Status" ObjectSize="1 Bit" ReadFlag="Enabled" WriteFlag="Disabled" CommunicationFlag="Enabled" TransmitFlag="Enabled" UpdateFlag="Disabled" ReadOnInitFlag="Disabled" DatapointType="" />
</ComObjectTable>
<ComObjectRefs>
<ComObjectRef Id="M-00FA_A-0001-0B-0000_O-1_R-1" RefId="M-00FA_A-0001-0B-0000_O-1" />
<ComObjectRef Id="M-00FA_A-0001-0B-0000_O-2_R-2" RefId="M-00FA_A-0001-0B-0000_O-2" />
<ComObjectRef Id="M-00FA_A-0001-0B-0000_O-3_R-3" RefId="M-00FA_A-0001-0B-0000_O-3" />
</ComObjectRefs>
<AddressTable MaxEntries="65000" />
<AssociationTable MaxEntries="65000" />
<LoadProcedures>
<LoadProcedure MergeId="2">
<LdCtrlRelSegment AppliesTo="full" LsmIdx="4" Size="0" Mode="0" Fill="0" />
</LoadProcedure>
<LoadProcedure MergeId="4">
<LdCtrlWriteRelMem ObjIdx="4" Offset="0" Size="0" Verify="true" />
</LoadProcedure>
</LoadProcedures>
<Options />
</Static>
<Dynamic>
<ChannelIndependentBlock>
<ParameterBlock Id="M-00FA_A-0001-0B-0000_PB-1" Name="ParameterPage" Text="Allgemeine Parameter">
<ComObjectRefRef RefId="M-00FA_A-0001-0B-0000_O-1_R-1" />
<ComObjectRefRef RefId="M-00FA_A-0001-0B-0000_O-2_R-2" />
<ComObjectRefRef RefId="M-00FA_A-0001-0B-0000_O-3_R-3" />
</ParameterBlock>
</ChannelIndependentBlock>
</Dynamic>
</ApplicationProgram>
</ApplicationPrograms>
<Hardware>
<Hardware Id="M-00FA_H-00001-10" Name="Sonoff S20" SerialNumber="00001" VersionNumber="10" HasIndividualAddress="true" HasApplicationProgram="true" IsIPEnabled="true">
<Products>
<Product Id="M-00FA_H-00001-10_P-123" Text="Schaltaktor" OrderNumber="123" IsRailMounted="false" DefaultLanguage="en-US" />
</Products>
<Hardware2Programs>
<Hardware2Program Id="M-00FA_H-00001-10_HP-0001-0B-0000" MediumTypes="MT-5">
<ApplicationProgramRef RefId="M-00FA_A-0001-0B-0000" />
</Hardware2Program>
</Hardware2Programs>
</Hardware>
</Hardware>
</Manufacturer>
</ManufacturerData>
</KNX>