| #include "interface_object.h"
 | |
| 
 | |
| void InterfaceObject::readPropertyDescription(uint8_t& propertyId, uint8_t& propertyIndex, bool& writeEnable, uint8_t& type, uint16_t& numberOfElements, uint8_t& access)
 | |
| {
 | |
|     PropertyDescription* descriptions = propertyDescriptions();
 | |
|     uint8_t count = propertyCount();
 | |
|     
 | |
|     PropertyDescription* desc = nullptr;
 | |
| 	
 | |
| 	// from KNX spec. 03.03.07 Application Layer (page 56) - 3.4.3.3  A_PropertyDescription_Read-service 
 | |
| 	// [...] and the Property of the object shall be addressed with 
 | |
| 	// a property_id OR with a property_index.The property_index shall be used ONLY if the property_id is zero. 
 | |
|     // [...]	
 | |
| 	// If the property_id in the A_PropertyDescription_Read - PDU is NOT zero, then the field property_index 
 | |
| 	// shall be IGNORED; the remote application process shall use the indicated property_id to access the Property 
 | |
| 	// description.The property_index in the A_PropertyDescription_Response - PDU shall in this case be : 
 | |
| 	// - the correct value of the Property index of the addressed Property, or 
 | |
| 	// - the value of the field property_index of the received A_PropertyDescription_Read - PDU. 
 | |
| 	// For new implementations the property_index shall contain the correct value of the addressed Property. 
 | |
| 	// If the remote application process has a problem, e.g.Interface Object or Property does not exist, then the 
 | |
| 	// max_nr_of_elem of the A_PropertyDescription_Response - PDU shall be zero. 	
 | |
|     if (propertyId != 0)
 | |
|     {   
 | |
| 	    for (uint8_t i = 0; i < count; i++)
 | |
|         {
 | |
|             PropertyDescription d = descriptions[i];
 | |
|             if (d.Id != propertyId)
 | |
|                 continue;
 | |
|             
 | |
|             desc = &d;
 | |
|             propertyIndex = i;
 | |
|             break;
 | |
|         }
 | |
|     }
 | |
|     else
 | |
|     {
 | |
| 	    // If the property_id in the A_PropertyDescription_Read - PDU is zero, the remote application process shall 
 | |
| 	    // use the indicated property_index to access the Property description.The property_index in the 
 | |
| 	    // A_PropertyDescription_Response - PDU shall be the value of the field property_index of the received 
 | |
| 	    // A_PropertyDescription_Read - PDU 	    
 | |
|         if (propertyIndex >= 0 && propertyIndex < count) 
 | |
|         {
 | |
|             desc = &descriptions[propertyIndex];
 | |
|         }
 | |
|     }
 | |
|     
 | |
| 	if (desc != nullptr)
 | |
| 	{
 | |
| 		propertyId = desc->Id;
 | |
| 		writeEnable = desc->WriteEnable;
 | |
| 		type = desc->Type;
 | |
| 		numberOfElements = desc->MaxElements;
 | |
| 		access = desc->Access;        
 | |
| 	}
 | |
| 	else
 | |
| 	{
 | |
| 		numberOfElements = 0;
 | |
| 	}
 | |
| } |