Fix PropDescRead and add comments from spec
This commit is contained in:
parent
2a4473c5ff
commit
daf1cabedf
@ -6,12 +6,24 @@ void InterfaceObject::readPropertyDescription(uint8_t& propertyId, uint8_t& prop
|
||||
uint8_t count = propertyCount();
|
||||
|
||||
PropertyDescription* desc = nullptr;
|
||||
|
||||
// from KNX spec. 03.03.07 Application Layer (page 56) - 3.4.3.3 A_PropertyDescription_Read-service
|
||||
// [...] and the Property of the object shall be addressed with
|
||||
// a property_id OR with a property_index.The property_index shall be used ONLY if the property_id is zero.
|
||||
// [...]
|
||||
// If the property_id in the A_PropertyDescription_Read - PDU is NOT zero, then the field property_index
|
||||
// shall be IGNORED; the remote application process shall use the indicated property_id to access the Property
|
||||
// description.The property_index in the A_PropertyDescription_Response - PDU shall in this case be :
|
||||
// - the correct value of the Property index of the addressed Property, or
|
||||
// - the value of the field property_index of the received A_PropertyDescription_Read - PDU.
|
||||
// For new implementations the property_index shall contain the correct value of the addressed Property.
|
||||
// If the remote application process has a problem, e.g.Interface Object or Property does not exist, then the
|
||||
// max_nr_of_elem of the A_PropertyDescription_Response - PDU shall be zero.
|
||||
if (propertyId != 0)
|
||||
{
|
||||
|
||||
for (uint8_t i = 0; i < count; i++)
|
||||
{
|
||||
PropertyDescription d = descriptions[propertyIndex];
|
||||
PropertyDescription d = descriptions[i];
|
||||
if (d.Id != propertyId)
|
||||
continue;
|
||||
|
||||
@ -22,6 +34,10 @@ void InterfaceObject::readPropertyDescription(uint8_t& propertyId, uint8_t& prop
|
||||
}
|
||||
else
|
||||
{
|
||||
// If the property_id in the A_PropertyDescription_Read - PDU is zero, the remote application process shall
|
||||
// use the indicated property_index to access the Property description.The property_index in the
|
||||
// A_PropertyDescription_Response - PDU shall be the value of the field property_index of the received
|
||||
// A_PropertyDescription_Read - PDU
|
||||
if (propertyIndex >= 0 && propertyIndex < count)
|
||||
{
|
||||
desc = &descriptions[propertyIndex];
|
||||
@ -36,4 +52,8 @@ void InterfaceObject::readPropertyDescription(uint8_t& propertyId, uint8_t& prop
|
||||
numberOfElements = desc->MaxElements;
|
||||
access = desc->Access;
|
||||
}
|
||||
else
|
||||
{
|
||||
numberOfElements = 0;
|
||||
}
|
||||
}
|